Temperature controller Ascon Teconologic K85

Termoregolatore Ascon Tecnologic K85

ASCON TECNOLOGIC K85, REGULATOR MINI-PROGRAMMER FOR RAIL DIN, 3 RS485 OUTPUT:

  • Digital controller and mini-programmer with independent timers for DIN rail mounting
  • 4 DIN modules, 70 x 84 mm, depth 60 mm
  • IP40 front panel protection for indoor use
  • 1 red display 4 digit, h 12 mm + 3 LED bar graph
  • 1 input for temperature probes: tc J, K, S; infrared sensors J and K; RTD Pt 100 IEC; PTC KTY81-121 (990 Ω @ 25 ° C); NTC 103AT-2 (10K @ 25 ° C), for signals in mV 0 … 50 mV, 0 mV … 60, 12 … 60 mV or normalized signals 0/4 … 20 mA, 0. .1 V, 0/1 … 5 V, 0/2 … 10 V
  • 2 digital inputs for voltage-free contacts
  • Power supply: 24 VAC / VDC, 100 … 240 VAC / VDC ± 10%
  • Up to 3 relay outputs or voltage for driving SSR
  • Auxiliary power output: 12 VDC / 20 mA max
  • ON / OFF, ON / OFF Neutral Zone with time compressor protection, PID single and double action with overshoot control, Self-tune and control the doldrums (guaranteed soak)
  • Overall accuracy: ± 0.5% fs + 1 digit; tc S ± 1% fs + 1 digit
  • RS 485 isolated, MODBUS RTU (JBUS)
  • 1 Program 8 ramp and recovery segments, 2 events and control the doldrums
  • independent timers with 4 modes of operation
  • Wattmeter for the calculation of the instantaneous power consumed and energy

MECHANICAL PROPERTIES OF TEMPERATURE:

  • Housing: plastic, self-extinguishing UL 94 V0
  • installation: mounting on Omega DIN rail
  • Size: 70×84 mm (1/8 DIN), depth 98 mm
  • Display: Single Display, 4-digit, red, h 12 mm + 3 LED bar graph
  • weight: 180 g approx
  • Rear terminal block: 12 screw terminals (screw M3, for cables from 0.25 to 2.5 mm2 or from AWG 22 to AWG 14)
  • degree of protection: – front IP 65 protection in accordance with EN 60070-1 for indoor locations – Terminals: IP20
  • Input for TC, RTD, PTC, NTC, mA or V
  • user calibration
  • PID control H / C with overshoot control, self-tune and two algorithms autotuning
  • 8-segment programmer function with recovery segments, 2 events and control stasis (guaranteed soak)
  • independent timers with 4 modes of operation
  • On / OFF H / C with time compressor protection
  • Wattmeter for the calculation of the instantaneous power consumed and energy
  • Digital set point retransmission
  • Counter hours or days worked with programmable threshold for programmed maintenance
  • Function delay on power
  • Sequence programmable parameters
  • Ramps on set point change
  • Serial communication via RS485 with Modbus RTU protocol